{"id":15540,"date":"2023-12-19T18:41:09","date_gmt":"2023-12-19T18:41:09","guid":{"rendered":"https:\/\/liquidinstruments.com\/?p=15540"},"modified":"2025-07-10T00:38:08","modified_gmt":"2025-07-10T00:38:08","slug":"configuring-multiple-moku-devices-with-a-single-labview-program","status":"publish","type":"post","link":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/","title":{"rendered":"Automating device characterization with LabVIEW","gt_translate_keys":[{"key":"rendered","format":"text"}]},"content":{"rendered":"<p><span style=\"font-weight: 400;\">Device characterization and validation often require more than one instrument to fully qualify your design. You may need an oscilloscope, spectrum analyzer, digital filters, and other instruments to verify the device or component. While flexible, FPGA-based solutions like Moku can solve this challenge by consolidating many software-defined instruments into a single device, you may need to increase channel count or the number of instruments you can use simultaneously. Using <a href=\"https:\/\/liquidinstruments.com\/products\/apis\/\">APIs<\/a> for industry-standard programs like <\/span><a href=\"https:\/\/liquidinstruments.com\/products\/apis\/labview-api\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">LabVIEW<\/span><\/a><span style=\"font-weight: 400;\">, it\u2019s easy to automate and streamline this test configuration for repeated, controlled validation.<\/span><\/p>\n<h2><b>Configuring the setup<\/b><\/h2>\n<p><a href=\"https:\/\/liquidinstruments.com\/multi-instrument-mode\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">Multi-instrument Mode<\/span><\/a><span style=\"font-weight: 400;\"> is a feature available on Moku devices that enables you to deploy up to four software-defined instruments simultaneously through partial FPGA reconfiguration. Specifically with <\/span><a href=\"https:\/\/liquidinstruments.com\/products\/hardware-platforms\/mokugo\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">Moku:Go<\/span><\/a><span style=\"font-weight: 400;\">, you can deploy two instruments at once. If more flexibility is required, the LabVIEW API is available to help you to control multiple Moku devices simultaneously from a single software interface.&nbsp;<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For this example, we are using two Moku:Go devices. This approach allows us to collect data from multiple individual instruments on each device simultaneously. We can then use the LabVIEW API to control both devices and all instruments from one interface. In this experiment, our device under test (DUT) is a Texas Instruments LM386 Low Voltage Audio Power Amplifier.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For validation, we first use the programmable DC power supply on the first Moku:Go device to power the DUT. Next, we apply a stimulus with the <\/span><a href=\"https:\/\/liquidinstruments.com\/products\/integrated-instruments\/oscilloscope\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">Oscilloscope<\/span><\/a><span style=\"font-weight: 400;\">\u2019s embedded <\/span><a href=\"https:\/\/liquidinstruments.com\/products\/integrated-instruments\/waveform-generator\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">Waveform Generator<\/span><\/a><span style=\"font-weight: 400;\">. Then, we compare the input signal to the DUT output signal, and use the Oscilloscope data to calculate a gain factor. Simultaneously on the second Moku:Go device, we use the <\/span><a href=\"https:\/\/liquidinstruments.com\/products\/integrated-instruments\/spectrum-analyzer\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">Spectrum Analyzer<\/span><\/a><span style=\"font-weight: 400;\"> to examine the DUT output signal in the frequency domain, and use the <\/span><a href=\"https:\/\/liquidinstruments.com\/products\/integrated-instruments\/digital-filter-box\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">Digital Filter Box<\/span><\/a><span style=\"font-weight: 400;\"> to remove higher-order harmonics in the DUT output signal.&nbsp;<\/span><\/p>\n<p><span style=\"font-weight: 400;\">In the first Moku:Go, we can configure Slot 1 as the Oscilloscope and Slot 2 as the Spectrum Analyzer. In the second Moku:Go, we can deploy the Digital Filter Box in Slot 1 and the Spectrum Analyzer in Slot 2. We also leverage the Oscilloscope\u2019s embedded Waveform Generator and the Moku device\u2019s programmable power supply, allowing us to essentially deploy six instruments simultaneously through two Moku:Go devices (Figure 1). Figure 2 depicts the wiring diagram of the test setup.<\/span><\/p>\n<p><img decoding=\"async\" class=\"wp-image-15541 size-full aligncenter\" src=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure1.png\" alt=\"The instrument configurations for both Moku:Go devices, including the DC Power Supply, Oscilloscope, Waveform Generator, Spectrum Analyzer, and Digital Filter Box \" width=\"512\" height=\"364\" srcset=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure1.png 512w, https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure1-300x213.png 300w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><\/p>\n<p style=\"text-align: center;\"><span style=\"font-weight: 400;\">Figure 1: The instrument configurations for both Moku:Go devices.<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" class=\"wp-image-15542 size-full aligncenter\" src=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure2-1.png\" alt=\"Test setup block diagram between the Oscilloscope (OSC), Spectrum Analyzer (SA), Digital Filter Box (DFB), and programmable power supply units (PPSU)\" width=\"512\" height=\"262\" srcset=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure2-1.png 512w, https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure2-1-300x154.png 300w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><\/p>\n<p style=\"text-align: center;\"><span style=\"font-weight: 400;\">Figure 2: Test setup block diagram between the Oscilloscope (OSC), Spectrum Analyzer (SA), Digital Filter Box (DFB), and programmable power supply units (PPSU).<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Using LabVIEW, we created a <a href=\"https:\/\/www.britannica.com\/technology\/graphical-user-interface\" target=\"_blank\" rel=\"noopener\">graphical user interface<\/a> (GUI) to display multiple instrument graphs and measurements simultaneously, from multiple software-defined instruments and two Moku:Go devices, including configuration parameters and settings (Figure 3). The signal routing between instrument slots and the analog inputs and outputs can be found on the left side of the GUI. The first Moku:Go provides power and the input signal to the DUT. It simultaneously characterizes the DUT output signal in the time and frequency domains. The second Moku:Go employs the Digital Filter Box to remove higher-order harmonics from the DUT output signal.<\/span><\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-15543 size-full\" src=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png\" alt=\"LabVIEW GUI with the first Moku:Go graphs visible on top and the second Moku:Go graphs visible on the bottom\" width=\"512\" height=\"294\" srcset=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png 512w, https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1-300x172.png 300w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><\/p>\n<p style=\"text-align: center;\"><span style=\"font-weight: 400;\">Figure 3: LabVIEW GUI with the first Moku:Go graphs visible on top and the second Moku:Go graphs visible on the bottom.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The LabVIEW block diagram is shown in Figure 4. From left to right, we must start by configuring Multi-instrument Mode for the first Moku:Go device, then configure the instruments within each slot, and then repeat this process for the second device. This configuration allows us to run the blocks of code controlling all instruments in parallel, enabling a more streamlined and condensed test setup than integrating in multiple fixed-function hardware devices, often from a wide range of manufacturers.<\/span><\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-15544 size-full\" src=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure4-1.png\" alt=\"LabVIEW block diagram detailing each instrument\u2019s configuration settings\" width=\"512\" height=\"318\" srcset=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure4-1.png 512w, https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure4-1-300x186.png 300w\" sizes=\"(max-width: 512px) 100vw, 512px\" \/><\/p>\n<p style=\"text-align: center;\"><span style=\"font-weight: 400;\">Figure 4: LabVIEW block diagram detailing each instrument\u2019s configuration settings.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This configuration, combined with the GUI, allows us to both stimulate the DUT and see the results in real time. For example, adjusting the gain setting potentiometer on the DUT would allow us to see the output signal change in real time on both the Oscilloscope and Spectrum Analyzer, alongside measurements for frequency, amplitude, and gain. Furthermore, by adjusting the Digital Filter Box parameters, we can create a real-time lowpass filter to remove higher-order harmonics in the DUT output signal, with results shown in Figure 5.<\/span><\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-15545 size-full\" src=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure5.png\" alt=\"The DUT output signal before lowpass filter (top) and after lowpass filter (bottom). Measurements are displayed for a 5 kHz fundamental and a 10 kHz second harmonic.\" width=\"339\" height=\"512\" srcset=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure5.png 339w, https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure5-199x300.png 199w, https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure5-300x453.png 300w\" sizes=\"(max-width: 339px) 100vw, 339px\" \/><\/p>\n<p style=\"text-align: center;\"><span style=\"font-weight: 400;\">Figure 5: The DUT output signal before lowpass filter (top) and after lowpass filter (bottom).&nbsp; Measurements are displayed for a 5 kHz fundamental and a 10 kHz second harmonic.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Using LabVIEW to initiate real-time control and signal processing on Moku devices enables a much better way to view data and adjust settings while performing repetitive device validation.<\/span><\/p>\n<h2><b>Transitioning from manual to automated test<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">When using Moku devices with APIs, it\u2019s simple to transition back and forth from automated scripts to the Moku: application. If you need to perform additional troubleshooting, manual investigation, or validate your setup, you can interrupt the automated test and open the intuitive user interface. In the event of an error or loss of signal, you can enter the Moku: application and delve into each instrument and device for additional interrogation, with easy-to-navigate settings.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">By combining the flexibility of Moku software-defined instrumentation with the ability to automate measurements using the LabVIEW API, you can quickly scale, adapt, and monitor your test setup with real-time instrument configuration and control.<\/span><\/p>\n<h2>Questions?<\/h2>\n<h3><b>Get answers to FAQs in our Knowledge Base<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">If you have a question about a device feature or instrument function, check out our extensive <\/span><a href=\"https:\/\/knowledge.liquidinstruments.com\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">Knowledge Base<\/span><\/a><span style=\"font-weight: 400;\"> to find the answers you\u2019re looking for. You can also quickly see popular articles and refine your search by product or topic.<\/span><\/p>\n<h3><b>Join our User Forum to stay connected<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Want to request a new feature? Have a support tip to share? From use case examples to new feature announcements and more, the <\/span><a href=\"https:\/\/forum.liquidinstruments.com\/\" rel=\"noopener\"><span style=\"font-weight: 400;\">User Forum<\/span><\/a><span style=\"font-weight: 400;\"> is your one-stop shop for product updates, as well as connection to Liquid Instruments and our global user community.<\/span><\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"excerpt":{"rendered":"<p>Device characterization and validation often require more than one instrument to fully qualify your design. You may need an oscilloscope, spectrum analyzer, digital filters, and other instruments to verify the device or component. While flexible, FPGA-based solutions like Moku can solve this challenge by consolidating many software-defined instruments into a single device, you may need [&hellip;]<\/p>\n","protected":false,"gt_translate_keys":[{"key":"rendered","format":"html"}]},"author":36,"featured_media":15543,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","footnotes":""},"categories":[3],"tags":[316],"class_list":["post-15540","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-ate","site-category-digital-filter-box","site-category-labview","site-category-mokugo","site-category-multi-instrument-mode","site-category-oscilloscpe","site-category-spectrum-analyzer","site-category-waveform-generator"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.0 (Yoast SEO v27.0) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Device Characterization and Validation with LabVIEW<\/title>\n<meta name=\"description\" content=\"Learn how to automate your device characterization process using LabVIEW and Moku for efficient testing and validation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Automating device characterization with LabVIEW\" \/>\n<meta property=\"og:description\" content=\"Learn how to automate your device characterization process using LabVIEW and Moku for efficient testing and validation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/\" \/>\n<meta property=\"og:site_name\" content=\"Liquid Instruments\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/LiquidInstruments\/\" \/>\n<meta property=\"article:published_time\" content=\"2023-12-19T18:41:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-10T00:38:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"512\" \/>\n\t<meta property=\"og:image:height\" content=\"294\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"mmcardle\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@liquidinstrmnts\" \/>\n<meta name=\"twitter:site\" content=\"@liquidinstrmnts\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"mmcardle\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/\"},\"author\":{\"name\":\"mmcardle\",\"@id\":\"https:\/\/liquidinstruments.com\/#\/schema\/person\/a3d838bd1576c0f8f6fb52f263bd338a\"},\"headline\":\"Automating device characterization with LabVIEW\",\"datePublished\":\"2023-12-19T18:41:09+00:00\",\"dateModified\":\"2025-07-10T00:38:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/\"},\"wordCount\":982,\"publisher\":{\"@id\":\"https:\/\/liquidinstruments.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png\",\"keywords\":[\"ATE\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/\",\"url\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/\",\"name\":\"Device Characterization and Validation with LabVIEW\",\"isPartOf\":{\"@id\":\"https:\/\/liquidinstruments.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png\",\"datePublished\":\"2023-12-19T18:41:09+00:00\",\"dateModified\":\"2025-07-10T00:38:08+00:00\",\"description\":\"Learn how to automate your device characterization process using LabVIEW and Moku for efficient testing and validation.\",\"breadcrumb\":{\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#primaryimage\",\"url\":\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png\",\"contentUrl\":\"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png\",\"width\":512,\"height\":294,\"caption\":\"LabVIEW GUI with the first Moku:Go graphs visible on top and the second Moku:Go graphs visible on the bottom\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/liquidinstruments.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Automating device characterization with LabVIEW\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/liquidinstruments.com\/#website\",\"url\":\"https:\/\/liquidinstruments.com\/\",\"name\":\"Liquid Instruments\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/liquidinstruments.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/liquidinstruments.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/liquidinstruments.com\/#organization\",\"name\":\"Liquid Instruments\",\"url\":\"https:\/\/liquidinstruments.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/liquidinstruments.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/i0.wp.com\/liquidinstruments.com\/wp-content\/uploads\/2020\/10\/BrandMark-Preferred-RGB-Color.png?fit=1000%2C924&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/liquidinstruments.com\/wp-content\/uploads\/2020\/10\/BrandMark-Preferred-RGB-Color.png?fit=1000%2C924&ssl=1\",\"width\":1000,\"height\":924,\"caption\":\"Liquid Instruments\"},\"image\":{\"@id\":\"https:\/\/liquidinstruments.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/LiquidInstruments\/\",\"https:\/\/x.com\/liquidinstrmnts\",\"https:\/\/www.instagram.com\/liquidinstruments\/\",\"https:\/\/www.linkedin.com\/company\/liquidinstruments\/\",\"https:\/\/www.youtube.com\/c\/LiquidInstruments\",\"https:\/\/vimeo.com\/liquidinstruments\"],\"hasMerchantReturnPolicy\":{\"@type\":\"MerchantReturnPolicy\",\"merchantReturnLink\":\"https:\/\/liquidinstruments.com\/support\/warranty-repairs-and-service\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/liquidinstruments.com\/#\/schema\/person\/a3d838bd1576c0f8f6fb52f263bd338a\",\"name\":\"mmcardle\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/liquidinstruments.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/c87d184ad2c207a8044a2c4f53a6a74745451f55e144a9a9f3cc8b3c04aa1671?s=96&d=wavatar&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/c87d184ad2c207a8044a2c4f53a6a74745451f55e144a9a9f3cc8b3c04aa1671?s=96&d=wavatar&r=g\",\"caption\":\"mmcardle\"}}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Device Characterization and Validation with LabVIEW","description":"Learn how to automate your device characterization process using LabVIEW and Moku for efficient testing and validation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/","og_locale":"en_US","og_type":"article","og_title":"Automating device characterization with LabVIEW","og_description":"Learn how to automate your device characterization process using LabVIEW and Moku for efficient testing and validation.","og_url":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/","og_site_name":"Liquid Instruments","article_publisher":"https:\/\/www.facebook.com\/LiquidInstruments\/","article_published_time":"2023-12-19T18:41:09+00:00","article_modified_time":"2025-07-10T00:38:08+00:00","og_image":[{"width":512,"height":294,"url":"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png","type":"image\/png"}],"author":"mmcardle","twitter_card":"summary_large_image","twitter_creator":"@liquidinstrmnts","twitter_site":"@liquidinstrmnts","twitter_misc":{"Written by":"mmcardle","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#article","isPartOf":{"@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/"},"author":{"name":"mmcardle","@id":"https:\/\/liquidinstruments.com\/#\/schema\/person\/a3d838bd1576c0f8f6fb52f263bd338a"},"headline":"Automating device characterization with LabVIEW","datePublished":"2023-12-19T18:41:09+00:00","dateModified":"2025-07-10T00:38:08+00:00","mainEntityOfPage":{"@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/"},"wordCount":982,"publisher":{"@id":"https:\/\/liquidinstruments.com\/#organization"},"image":{"@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#primaryimage"},"thumbnailUrl":"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png","keywords":["ATE"],"articleSection":["Blog"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/","url":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/","name":"Device Characterization and Validation with LabVIEW","isPartOf":{"@id":"https:\/\/liquidinstruments.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#primaryimage"},"image":{"@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#primaryimage"},"thumbnailUrl":"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png","datePublished":"2023-12-19T18:41:09+00:00","dateModified":"2025-07-10T00:38:08+00:00","description":"Learn how to automate your device characterization process using LabVIEW and Moku for efficient testing and validation.","breadcrumb":{"@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#primaryimage","url":"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png","contentUrl":"https:\/\/liquidinstruments.com\/wp-content\/uploads\/2023\/12\/Figure3-1.png","width":512,"height":294,"caption":"LabVIEW GUI with the first Moku:Go graphs visible on top and the second Moku:Go graphs visible on the bottom"},{"@type":"BreadcrumbList","@id":"https:\/\/liquidinstruments.com\/blog\/configuring-multiple-moku-devices-with-a-single-labview-program\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/liquidinstruments.com\/"},{"@type":"ListItem","position":2,"name":"Automating device characterization with LabVIEW"}]},{"@type":"WebSite","@id":"https:\/\/liquidinstruments.com\/#website","url":"https:\/\/liquidinstruments.com\/","name":"Liquid Instruments","description":"","publisher":{"@id":"https:\/\/liquidinstruments.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/liquidinstruments.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/liquidinstruments.com\/#organization","name":"Liquid Instruments","url":"https:\/\/liquidinstruments.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/liquidinstruments.com\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/liquidinstruments.com\/wp-content\/uploads\/2020\/10\/BrandMark-Preferred-RGB-Color.png?fit=1000%2C924&ssl=1","contentUrl":"https:\/\/i0.wp.com\/liquidinstruments.com\/wp-content\/uploads\/2020\/10\/BrandMark-Preferred-RGB-Color.png?fit=1000%2C924&ssl=1","width":1000,"height":924,"caption":"Liquid Instruments"},"image":{"@id":"https:\/\/liquidinstruments.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/LiquidInstruments\/","https:\/\/x.com\/liquidinstrmnts","https:\/\/www.instagram.com\/liquidinstruments\/","https:\/\/www.linkedin.com\/company\/liquidinstruments\/","https:\/\/www.youtube.com\/c\/LiquidInstruments","https:\/\/vimeo.com\/liquidinstruments"],"hasMerchantReturnPolicy":{"@type":"MerchantReturnPolicy","merchantReturnLink":"https:\/\/liquidinstruments.com\/support\/warranty-repairs-and-service\/"}},{"@type":"Person","@id":"https:\/\/liquidinstruments.com\/#\/schema\/person\/a3d838bd1576c0f8f6fb52f263bd338a","name":"mmcardle","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/liquidinstruments.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/c87d184ad2c207a8044a2c4f53a6a74745451f55e144a9a9f3cc8b3c04aa1671?s=96&d=wavatar&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c87d184ad2c207a8044a2c4f53a6a74745451f55e144a9a9f3cc8b3c04aa1671?s=96&d=wavatar&r=g","caption":"mmcardle"}}]}},"gt_translate_keys":[{"key":"link","format":"url"}],"_links":{"self":[{"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/posts\/15540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/users\/36"}],"replies":[{"embeddable":true,"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/comments?post=15540"}],"version-history":[{"count":3,"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/posts\/15540\/revisions"}],"predecessor-version":[{"id":25015,"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/posts\/15540\/revisions\/25015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/media\/15543"}],"wp:attachment":[{"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/media?parent=15540"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/categories?post=15540"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/liquidinstruments.com\/wp-json\/wp\/v2\/tags?post=15540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}